5
VFD-S Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-33
Example 2 (Pr.5-07 = d2): Continuously executes program cycles
The diagram below shows the PLC program stepping through each speed and the
automatically starting again. To stop the PLC program, one must either pause the
program or turn it off (Refer to Pr.4-05 to 4-08 value d17 and d18).
Frequency
60Hz
50Hz
40Hz
30Hz
20Hz
15Hz
10Hz
0Hz
5-09
5-11
5-12 5-13
5-14
5-15 5-16
5-00
5-01
5-02
5-03
5-04
5-05
5-06
Program step
complete
Program operation
completed
5-00
5-09
5-10
5Hz
Master freq.=5Hz
5-00=10 Hz
5-01=20 Hz
5-02=40 Hz
5-03=60 Hz
5-04=50 Hz
5-05=30 Hz
5-06=15 Hz
4-07=d17
3-05=d11
3-06=d12
5-07=d2
5-08=d0
5-09=10 Sec
5-10=10
5-11=12
5-12
Sec
Sec
=15 Sec
5-13=15 Sec
5-14=8 Sec
5-15=17 Sec
5-16=17 Sec
5-10
Time
(Sec)
Example 3 (Pr. 5-07 = d3) Execute one cycle step by step:
The example shows how the PLC can perform one cycle at a time, within a complete cycle.
Each step will use the acceleration/deceleration times in Pr.1-09 to Pr.1-12. It should be
noticed that the time each step spends at its intended frequency is diminished, due to the
time spent during acceleration/deceleration.
Frequency
60Hz
50Hz
40Hz
30Hz
20Hz
15Hz
10Hz
0Hz
5-13
5-14
5-15
5-16
5-03
5-04
5-05
5-06
Program step
complete
Program operation
completed
t t
tt
5Hz
5-09
Master freq.=5Hz
5-00=10 Hz
5-01=20 Hz
5-02=40 Hz
5-03=60 Hz
5-04=50 Hz
5-05=30 Hz
5-06=15 Hz
4-07=d17
3-05=d11
3-06=d12
5-07=d3
5-08=d0
5-09=10
5-10=10
5-11=12
5-12
Sec
Sec
Sec
=15 Sec
5-13=15 Sec
5-14=8 Sec
5-15=17 Sec
5-16=17 Sec
Time