Chapter 3 Element Function|ScrEdit Software User Manual
3-58 Revision Apr. 30th, 2007, 2007PDD23000002
4. Then, the drawing flag of the trend graph, i.e. Trend Draw is $1002.0 and the clear flag of the trend
graph, i.e. Trend Clear is $1002.8; the drawing flag of the X-Y chart, i.e. X-Y Draw is $1002.1 and
the clear flag of the X-Y chart, i.e. X-Y Clear is $1002.9.
5. Create a momentary button, which the memory address is set to $1002.0 on the screen and set
OFF macro as follows:
CLRB $1002.8
Create a momentary button, which the memory address is set to $1002.8 on the screen and set
OFF macro as follows:
CLRB $1002.0
Create a momentary button, which the memory address is set to $1002.1 on the screen and set
OFF macro as follows:
CLRB $1002.9
Create a momentary button, which the memory address is set to $1002.9 on the screen and set
OFF macro as follows:
CLRB $1002.1