LCP-2488D4RXXR
DELTA ELECTRONICS, INC.
14 Revision: S4
09/14/2010
www.deltaww.com
Digital Diagnostic Monitor Accuracy
Parameter Typical Value Note
Transceiver Temperature
± 3℃
1
Power Supply Voltage ± 3% 2
TX Bias Current ± 10%
TX Optical Power ± 3dB 3
RX Optical Power ± 3dB 4
Notes:
1) Temperature is measured internal to the transceiver.
2) Voltage is measured internal to the transceiver.
Regulatory Compliance
Test Item Reference
Note
(#1)
Electromagnetic Interference
EMC
FCC Class B
EN 55022 Class B
CISPR 22
(#2) Immunity:
Radio Frequency
Electromagnetic Field
EN 61000-4-3
IEC 1000-4-3
(#3) Immunity:
Electrostatic Discharge to the
Duplex SC Receptacle
EN 61000-4-2
IEC 1000-4-2
IEC 801.2
(#4) Electrostatic Discharge to
the Electrical Pins
MIL-STD-883C Method 3015.4
EIAJ#1988.3.2B
Version 2,
Machine model