Delta Electronics Multimode SFP Transceiver LCP-1250A4FDRx Uživatelský manuál Strana 12

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 14
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 11
LCP-1250A4FDRx
DELTA ELECTRONICS, INC.
12 09/20/2011
Rev. S0
www.deltaww.com
4)
State/ Control Bits
Byte Bit Name Description
110 7 Tx Disable State Digital state of the Tx disable input pin
110
6
Soft Tx Disable
Read/ Write bit that allow software disable of laser
110 5 Reserved
110 4 Rate Select tate NA
110
3
Soft Rate Select
NA
110 2 Tx Fault Digital state of the Tx fault output pin
110 1 LOS Digital state of the LOS output pin.
110
0
Data_Ready_Bar
NA
5)
Optional Set of Alarm and Warning
Byte
B
i
t
Name
Description
112 7 Temp High Alarm Set when internal temperature exceeds high alarm level
112 6 Temp Low Alarm Set when internal temperature is below low alarm level
112
5
Vcc High Alarm
Set when internal supply voltage exceeds high alarm level
112 4 Vcc Low Alarm Set when internal supply voltage is below low alarm level
112 3 Tx Bias High Alarm Set when Tx Bias current exceeds high alarm level
112
2
Tx Bias Low Alarm
Set when Tx Bias current is below low alarm level
112 1 Tx Power High Alarm Set when Tx output power exceeds high alarm level
112 0 Tx Power Low Alarm Set when Tx output power is below low alarm level
113
7
Rx Power High Alarm
Set when
received
power exceeds high alarm level
113 6 Rx Power Low Alarm Set when received power is below low alarm level
113 5-0 Reserved
11
6
7
Temp High Warning
Set when internal temperature exceeds high warning level
116 6 Temp Low Warning Set when internal temperature is below low warning level
116 5 Vcc High Warning Set when internal supply voltage exceeds high warning level
116
4
Vcc L
ow Warning
Set when internal supply voltage is below low warning level
116 3 Tx Bias High Warning Set when Tx Bias current exceeds high warning level
116 2 Tx Bias Low Warning Set when Tx Bias current is below low warning level
116
1
Tx Power High Warni
ng
Set when Tx output power exceeds high warning level
116 0 Tx Power Low Warning Set when Tx output power is below low warning level
117 7 Rx Power High Warning Set when received power exceeds high warning level
117
6
Rx Power Low Warning
Set when rece
ived power is below low warning level
117 5-0 Reserved
Digital Diagnostic Monitor Accuracy
Parameter Typical Value Note
Transceiver Temperature ± 3˚C 1
Power Supply Voltage
±
3%
2
TX Bias Current
±
10%
TX Optical Power ± 3dB
RX Optical Power
±
3
dB
Notes:
1) Temperature is measured internal to the transceiver
2) Voltage is measured internal to the transceiver
Zobrazit stránku 11