LCP-10G3A4EDRx-G
DELTA ELECTRONICS, INC.
15 Revision: S3
2013/05/14
www.deltaww.com
State/ Control Bits
Byte
Bit
Name
Description
110 7 Tx Disable State Digital state of the Tx disable input pin
110 6 Soft Tx Disable Read/ Write bit that allow software disable of laser
110
5
Reserved
110 4 Rate Select State Rate Select State
110 3 Soft Rate Select Software Rate Select State
110
2
Tx Fault
Digital state of the Tx fault output pin
110 1 LOS Digital state of the LOS output pin.
110 0 Data_Ready_Bar NA
Optional Set of Alarm and Warning
Byte Bit Name Description
112 7 Temp High Alarm Set when internal temperature exceeds high alarm level
112
6
Temp Low Alarm
Set when internal tem
perature is below low alarm level
112 5 Vcc High Alarm Set when internal supply voltage exceeds high alarm level
112 4 Vcc Low Alarm Set when internal supply voltage is below low alarm level
112
3
Tx Bias High Alarm
Set when Tx Bias current exceeds high
alarm level
112 2 Tx Bias Low Alarm Set when Tx Bias current is below low alarm level
112 1 Tx Power High Alarm Set when Tx output power exceeds high alarm level
112
0
Tx Power Low Alarm
Set when Tx output power is below low alarm level
113 7 Rx Power High Alarm Set when received power exceeds high alarm level
113 6 Rx Power Low Alarm Set when received power is below low alarm level
113
5
-
0
Reserved
116 7 Temp High Warning Set when internal temperature exceeds high warning level
116 6 Temp Low Warning Set when internal temperature is below low warning level
116
5
Vcc High Warning
Set when internal supply voltage exceeds high warning level
116 4 Vcc Low Warning Set when internal supply voltage is below low warning level
116 3 Tx Bias High Warning Set when Tx Bias current exceeds high warning level
116
2
Tx Bias Low Warning
Set when Tx Bias current is below low warning level
116 1 Tx Power High Warning Set when Tx output power exceeds high warning level
116 0 Tx Power Low Warning Set when Tx output power is below low warning level
117
7
Rx Power High Warning
Set when received power exceeds high warning level
117 6 Rx Power Low Warning Set when received power is below low warning level
117 5-0 Reserved
Digital Diagnostic Monitor Accuracy
Parameter Typical Value Note
Transceiver Temperature
±
3
˚
C
1
Power Supply Voltage ± 3% 2
TX Bias Current ± 10%
TX Optical Power
±
3
dB
RX Optical Power ± 3dB
Notes:
1) Temperature is measured internal to the transceiver
2)
Voltage is measured internal to the transceiver