DeviceNet Remote I/O Communication Module RTU-DNET
DVP-PLC Application Manual
37
Attribute
ID
Access
rule
Name Range Default Explanation
1 Special module unidentifiable
b5 ~ b15 Reserved
5 Get/Set Work mode 0 ~ 1 0
Work mode of special module
0: auto 1: custom
6 Get/Set Number of input data 0 ~ 8 N/A
Number of input data of special modules
connected
7 Get/Set
Number of output
data
0 ~ 8 N/A
Number of output data of special modules
connected
8 Reserved
9 Get Error code N/A Error code in special module
10~19 Reserved
20 Get/Set
Start CR for module
1 input data
N/A N/A
Start CR for the input data of special
module 1
21 Get/Set
Input data length for
module 1
N/A N/A Length of input data of special module 1
22 Get/Set
Start CR for module
2 input data
N/A
N/A
Start CR for the input data of special
module 2
23 Get/Set
Input data length for
module 2
N/A N/A Length of input data of special module 2
24 Get/Set
Start CR for module
3 input data
N/A N/A
Start CR for the input data of special
module 3
25 Get/Set
Input data length for
module 3
N/A
N/A Length of input data of special module 3
26 Get/Set
Start CR for module
4 input data
N/A
N/A
Start CR for the input data of special
module 4
27 Get/Set
Input data length for
module 4
N/A N/A Length of input data of special module 4
28 Get/Set
Start CR for module
5 input data
N/A N/A
Start CR for the input data of special
module 5
29 Get/Set
Input data length for
module 5
N/A
N/A Length of input data of special module 5
30 Get/Set
Start CR for module
6 input data
N/A
N/A
Start CR for the input data of special
module 6
31 Get/Set
Input data length for
module 6
N/A
N/A Length of input data of special module 6
32 Get/Set
Start CR for module
7 input data
N/A
N/A
Start CR for the input data of special
module 7
33 Get/Set
Input data length for
module 7
N/A
N/A Length of input data of special module 7
34 Get/Set
Start CR for module
8 input data
N/A
N/A
Start CR for the input data of special
module 8
35 Get/Set
Input data length for
module 8
N/A N/A Length of input data of special module 8
36 ~ 49 Reserved
50 Get/Set
Start CR for module
1 output data
N/A
N/A
Start CR for the output data of special
module 1
51 Get/Set
Output data length
N/A N/A Length of output data of special module 1