01-28 Skip Frequency 1 (upper limit) Factory setting 0.00
01-29 Skip Frequency 1 (lower limit)
Factory setting 0.00
01-30 Skip Frequency 2 (upper limit) Factory setting 0.00
01-31 Skip Frequency 2 (lower limit)
Factory setting 0.00
01-32 Skip Frequency 3 (upper limit) Factory setting 0.00
01-33 Skip Frequency 3 (lower limit)
Factory setting 0.00
Settings 0.00~400.00Hz
These parameters determine the skip frequencies of the AC drive.
Please use the following hierarchy when setting these parameters: Pr. 01-28 > Pr. 01-29 >
Pr. 01-30 > Pr. 01-31> Pr. 01-32 > Pr. 01-33. The Skip frequency will be disabled if this
rule is not followed.
The Skip Frequencies are useful when a motor has vibration at a specific frequency
bandwidth. By skipping this frequency, the vibration will be avoided.