Delta Electronics Ethernet Extension Module DOP Specifikace Strana 45

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 175
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 44
Train ing Kit O peratio n Manua l
2-2 8
The table below shows “Auto Graph Change” is “Yes”.
Example of the State Graphic
Table 2.5.4 Example of the State Graphic
Read
address
State Graphic Element Numeric Entry Element
Read address $326 Write address $326
Picture
Set the State Graphic
State 0 State 1 State 2
Properties
State Graphic Element
Data Type Data Format State Counts
Auto Picture
Change
Word
Unsigned
decimal
3 Yes
Execution
results
After creating the element, run “Compile” and download it to the HMI. Next,
input a non-zero value in the numeric entry element. Then, the state graphic
will automatically change and display the selected pictures according to the
defined picture change time. If the input value is “0”, the state graphic will reset
to the initial state without executing any action.