Train ing Kit O peratio n Manua l
2-5 4
No.
Property Function
Interlock
state
(6)
Interlock
address
The interlock address allows users to operate an element form this
particular address. It must be used along with the interlock state. If the
interlock state is “OFF”, this means the interlock address is operable
when the interlock state is “OFF”. In contrast, when the interlock state is
“ON”, this means the interlock address is operable when the interlock
state is “ON”.
The operations are as follows.
I First, create a maintained button and set its write memory address as
$44.0. Next, set its write memory as $555 from the numeric entry
element and the interlock address of the character entry element as
$44.0.
II To make the numeric entry element $555 operable, press the
maintained button $44.0 to enable $555.
Trigger
type
(7)
Trigger
The trigger types include “Before Writing” and “After Writing”.
Before Writing After Writing
Trigger
type
The activation bit is ON
before changing values.
Values are changed before
the activation bit is ON.
As the activation function only sets the trigger address to ON, users must
set the trigger address to OFF before re-activation.
Before writing: After writing: